Issue description
When the PCS client tries to update the license, the following error message is displayed: The license server returned an error. For detailed information, see the trace.
When a user clicks Update License on the Activate License (SM201510) form, the system cannot update the license because the application server cannot connect to the Acumatica licensing server. This occurs when a firewall rule blocks the outgoing connection.
Root cause
Outbound HTTPS traffic (port 443) from the Acumatica application server to the Acumatica licensing server is blocked by a network firewall, preventing the application server from connecting to the licensing server.
Workaround
Option 1 (recommended).
Ask your network or infrastructure team to allow outbound HTTPS traffic on port 443 from the Acumatica application server to the Acumatica licensing server.
To check connectivity, run the following PowerShell command on the application server:
Test-NetConnection -ComputerName licensing.acumatica.com -Port 443
If the TcpTestSucceeded value is False, the application server cannot establish a TCP connection to the licensing server on port 443. This may indicate that the connection is blocked by a firewall or another network restriction.
Option 2.
If the firewall changes cannot be made immediately, obtain a license file from Acumatica Support and click Upload License File on the Activate License (SM201510) form to upload the file. This allows you to activate the license without an outbound internet connection to the Acumatica licensing server.